{"product_id":"abb-pftl301e-0-2kn-pressductor-pillowblock-load-cell","title":"ABB PFTL301E-0.2KN Pressductor PillowBlock Load Cell","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE019050R200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePFTL301E-0.2KN\u003c\/strong\u003e Pressductor PillowBlock Load Cell, measures directional force generated by web tension at a roller bearing block. The device converts mechanical load into an electrical measurement signal for tension monitoring and control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9453%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 42.5097%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 57.0732%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003ePFTL301E-0.2KN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003ePart Number \/ Ordering Code\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003e3BSE019050R200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003ePressductor PillowBlock Load Cell \/ Web Tension Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eRated Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003e0.2 kN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eRated Force\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eApprox. 200 N \/ 45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eMeasurement Technology\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eABB Pressductor electromagnetic sensing principle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eMeasurement Direction\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eHorizontal or specified directional force component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eOverload Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eUp to 0.6 kN in the measurement direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eMechanical Deflection\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eApprox. 0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eMechanical Function\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eMeasures force acting through a roller bearing block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.5097%;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"width: 57.0732%;\"\u003eWeb tension measurement and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Pressductor Load Measurement\u003c\/h3\u003e\n\u003cp\u003eThe PFTL301E-0.2KN uses ABB Pressductor technology to sense mechanical force without a conventional strain-gauge load cell arrangement. The load cell detects the force component transferred through the pillow block and provides a measurement signal for web tension control.\u003c\/p\u003e\n\u003cp\u003eBecause the sensing point follows the mechanical load path, the installation must maintain the specified roller and bearing geometry. In addition, the load direction must correspond with the intended measurement axis.\u003c\/p\u003e\n\u003cp\u003eThe rated capacity is 0.2 kN, while the stated overload capacity reaches 0.6 kN in the measurement direction. Mechanical deflection is approximately 0.05 mm. Therefore, the mounting structure should avoid external forces that do not belong to the intended measurement path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What mechanical quantity does the PFTL301E-0.2KN measure?\u003cbr\u003eA: It measures a horizontal or specified directional force component transferred through the roller bearing block.\u003c\/p\u003e\n\u003cp\u003eQ: What is the rated capacity of the load cell?\u003cbr\u003eA: The rated capacity is 0.2 kN, equivalent to approximately 200 N or 45 lb.\u003c\/p\u003e\n\u003cp\u003eQ: What should be checked before installation?\u003cbr\u003eA: Verify the load direction, pillow block mounting geometry, mechanical load path, and cable routing. Avoid unintended mechanical forces on the sensing assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the load cell according to the roller and pillow block mechanical arrangement specified for the tension measurement system. First, confirm that the applied force acts along the intended measurement direction.\u003c\/p\u003e\n\u003cp\u003eNext, inspect the mounting surfaces for contamination, mechanical damage, or misalignment. Secure the pillow block without introducing external mechanical loads that could affect the measurement.\u003c\/p\u003e\n\u003cp\u003eRoute the signal cable separately from high-current motor, switching, and power cables where practical. Use the specified shielding and grounding arrangement for the associated ABB measurement system. Avoid unnecessary cable loops and excessive mechanical stress at the connection point.\u003c\/p\u003e\n\u003cp\u003eAfter mechanical installation, verify that the roller rotates freely and that the bearing assembly does not impose unintended lateral or axial forces on the load cell. Finally, check the measurement signal at zero load and confirm the response under a known mechanical load before placing the web tension loop into normal operation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53625804161333,"sku":"3BSE019050R200 PFTL301E-0.2KN","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/3BSE019050R200PFTL301E-0_Cocoai.jpg?v=1790056623","url":"https:\/\/www.newgenplc.com\/af\/products\/abb-pftl301e-0-2kn-pressductor-pillowblock-load-cell","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}